Deployment and Startup Notes (MxServiceCode / MxCAD Conversion Program)
Compiled from the actual installation package layout and startup scripts.
I. Program Location (Fixed Temp Path)
Two kinds of packages: standalone conversion program (MxConvert, mxcadassembly only) and backend service (MxServiceCode, contains BOTH the backend service and the conversion program — the complete superset). Download URLs: follow the "Link List" in the Entry Guide (take the row matching the need + platform; the Linux package is built for Ubuntu 20.04 x86_64).
Fixed temp path (download once, reuse across sessions; after the system cleans the temp dir, just re-download):
- Windows:
%TEMP%\MxCAD\(%TEMP%is the user's Temp directory environment variable; use it as-is in commands, no manual expansion needed) - Linux:
/tmp/MxCAD/
Follow the check steps in the Entry Guide: first determine what the task needs, then inspect what is in the temp path — nothing there → download the matching zip per need (conversion program only → standalone MxConvert package; backend service needed → MxServiceCode package, which includes the conversion program) and extract it to the temp path; conversion program only present → if only the conversion program is needed, run "III. Trial Version Expiry Check" first and it is ready to use; if the backend is needed, clear and re-download the backend package; backend package already extracted → run the expiry check + integrity verification, and if incomplete, clear and re-download. The temp path MUST be cleared before any re-download (each package has a fixed structure; the backend package is the complete superset). Do not scan other directories on the user's machine.
After extraction (Windows: a single top-level dir MxServiceCode_TryVersion\, same name as the zip)
MxServiceCode_TryVersion\ ← Top-level dir after extraction (same name as the zip)
├── MxServiceCode\
│ ├── NODE.JS后台程序开发.doc ← Official backend development tutorial (not an API doc)
│ ├── MxServiceCode.sln ← Solution file
│ └── MxServiceCode\ ← Project directory (the commands below run here)
│ ├── bin\node.exe ← Built-in Node runtime
│ ├── mxapp.js ← Entry point (command line)
│ ├── src\ ← TS sources (mxcad\ = API classes, sample\ = examples, MxCommand.ts = command registration)
│ ├── Mx2DNode.node ← Native module
│ ├── package.json ← npm run build for compilation
│ ├── test.bat ← Test script
│ ├── empty_template.dwg ← Blank template
│ ├── A3.dwg / BT.DWG ← Title block frame / title block sample blocks
│ └── t1.dwg / tree.dwg ← Test drawings
└── MxCAD\
└── Release\ ← Format conversion program directory (mxcadassembly.exe + runtime dependency dlls + mxcad_ini.json, mxcode.bin, mxiconv.data + **fonts\** + files\)After extraction (Linux: a single top-level dir MxServiceCode_TryVersion\, same name as the zip)
MxServiceCode_TryVersion\ ← Top-level dir after extraction (same name as the zip)
├── MxServiceCode\
│ ├── NODE.JS后台程序开发.doc ← Official backend development tutorial
│ └── MxServiceCode\ ← Project directory (no .sln; the built-in runtime is `node`, not bin\node.exe;
│ also contains start_demo_MxServiceCode.sh, start_demo_systemlib_MxServiceCode.sh, Linux启动说明.txt)
└── Linux\
└── MxCAD\ ← Format conversion program directory (mxcadassembly + runtime dependencies mx/so + mxcad_ini.json, mxcode.bin, mxiconv.data + **fonts\** + files\)Conversion program directory =
MxServiceCode_TryVersion\MxCAD\Release\under the Windows temp path,MxServiceCode_TryVersion\Linux\MxCAD\under the Linux temp path (orMxConvert_TryVersion\itself for the standalone MxConvert package); fonts needed for frontend drawing preview = thefonts\directory inside it (just copy it).
II. Running MxServiceCode Commands (no service to start)
Command mode is a standalone process; call the built-in node directly:
Windows (in the project directory):
bin\node.exe mxapp.js getcaddata file=t1.dwg outfile=t1.dwg.jsonLinux (in the project directory):
./node mxapp.js getcaddata file=t1.dwg outfile=t1.dwg.json linux=1Running node mxapp.js with no arguments prints version info and the log path.
⚠️ Built-in Node version limitation (tested):
bin\node.exeis v10.9.0 and supports CommonJS only — ESM (importsyntax /.mjs) throwsSyntaxErrordirectly; there is nofetch, no optional chaining, or other newer features. Helper scripts written for the built-in node must use CommonJS (require) +.js; when you need ESM, use the system Node.
Linux First Deployment (permission setup)
chmod 777 start_demo_MxServiceCode.sh
./start_demo_MxServiceCode.sh # the script already chmods mxcadassembly, mx/so, Mx2DNode.node, nodeIf it fails, use ./start_demo_systemlib_MxServiceCode.sh instead (uses the native libraries in the systemLib directory).
III. Format Conversion Program mxcadassembly (standalone invocation)
Windows (in the conversion program directory; the two forms are equivalent — pick by shell):
- cmd / PowerShell (bare JSON, the official-docs form, no encoding needed):
mxcadassembly.exe {"srcpath":"1.dwg","outname":"_trial.mxweb","outpath":"./out"}- Git Bash (percent-encoded string in quotes; bare JSON returns
read file errorin this shell, tested):
mxcadassembly.exe "[%7B%22srcpath%22%3A%221.dwg%22%2C%22outname%22%3A%22_trial.mxweb%22%2C%22outpath%22%3A%22.%2Fout%22%7D]"Linux (in the conversion program directory; bare JSON in single quotes):
chmod -R 777 mxcadassembly ./mx/so/*
./mxcadassembly '{"srcpath":"1.dwg","outname":"_trial.mxweb","outpath":"./out"}'(Equivalent alternative: ./mxcadassembly '[%7B%22srcpath%22%3A%221.dwg%22%2C%22outname%22%3A%22_trial.mxweb%22%2C%22outpath%22%3A%22.%2Fout%22%7D]')
Parameter form convention: the program accepts two equivalent forms — ① bare JSON (the official-docs form; works directly in cmd / PowerShell / Linux bash; in bash wrap it in single quotes); ② percent-hex-encoded string wrapped in square brackets (e.g.
{"a":1}→[%7B%22a%22%3A1%7D]; used internally by MxServiceCode; required in Git Bash).MxUtility.callMxCadAssemblyinside MxServiceCode already encapsulates this logic — in secondary development, prefer calling through the TS API; do not hand-build the command.
⚠️ Common pitfalls (tested)
- The encoding MUST include the
%prefix; plain hex (e.g.7b2261223a317d) returns{"code":1,"message":"read file error"}- In cmd.exe / batch files,
%is a batch-variable reference: a percent-encoded string gets mangled by expansion (returns{"code":1,"message":"read file error"}) — use the bare-JSON form in cmd- On Windows,
pythonmay be a Store placeholder program (silently no output); use the built-inbin\node.exefor temp scripts that generate encoded parameters- When the
convertcommand is unusable (wgh deprecated; see "MxServiceCodeCommandReference.md" detailed 1), this standalone invocation is the only way to do DWG→mxweb; the mxcad frontend only accepts mxweb
Trial Version Expiry Check
The conversion program is a trial version, valid for 6 months. If the conversion program is already in the temp path, you MUST run a test conversion before use (command-line mode, no GUI; run in the conversion program directory, using a bundled test drawing such as
1.dwg, with the output directory created first):Windows (cmd / PowerShell):
mxcadassembly.exe {"srcpath":"1.dwg","outname":"_trial.mxweb","outpath":"./out"}; Windows (Git Bash):mxcadassembly.exe "[%7B%22srcpath%22%3A%221.dwg%22%2C%22outname%22%3A%22_trial.mxweb%22%2C%22outpath%22%3A%22.%2Fout%22%7D]"; Linux:./mxcadassembly '{"srcpath":"1.dwg","outname":"_trial.mxweb","outpath":"./out"}'
- Returns
{"code":0,"message":"ok"}→ valid and usable; use it directly. - Returns non-zero → read the version string in
%TEMP%\MxNode\mxcad_*.log(recorded on every run; tested sample format:MxCAD TryVersion:7.0(2026-10-21 11:16)(64bit)(cooperate)):- The date in parentheses (e.g.
2026-10-21) = the trial start date;current date − trial start date > 5 months→ expired; re-download the zip and extract over the temp path (URL in the Entry Guide "Link List") - Not expired → program environment problem; debug according to the log
- The date in parentheses (e.g.
Common JSON parameters (see the official "Drawing Conversion Details" for the full list):
- Convert:
{"srcpath":"a.dwg","outname":"a.mxweb","outpath":"./out"}(paths relative to the conversion program directory; the outname extension decides the target format; mxweb→dwg must explicitly carry .dwg/.dxf; theoutpathdirectory must pre-exist) - Crop DWG:
{"cmd":"cut_dwg","bd_pt1_x":0,"bd_pt1_y":0,"bd_pt2_x":100,"bd_pt2_y":100,"srcpath":"a.dwg","outname":"cut.dwg"} - Output PDF:
{"srcpath":"a.dwg","outname":"a.pdf","outpath":"./out","ret_page_extents":true,"width":"2000","height":"2000","colorPolicy":"mono"}— nocmdfield (including it returns{"code":201}); output location follows the same rules as other conversions: the output directory isoutpath(falls back to the conversion program directory when omitted), the file name isoutname(whenoutnameis an absolute path, write directly to that location) srcpath/outpath/outnameall support absolute paths (including Chinese paths)- ⚠️ The
cmdparameter domain (such asprint_to_pdf) belongs to the MxServiceCode backend service interface; for direct mxcadassembly.exe calls only the parameters above are valid
IV. Secondary Development Workflow
- Modify
src/sample/*.tsor add a new file (API in "Mx2DNodeSecondaryDevAPIReference.md") - Register the command in
src/MxCommand.ts(see "MxServiceCodeCommandReference.md" section 6) - Compile:
npm run build(node_modules is bundled; if missing, usebin\node.exe node_modules\typescript\bin\tsc --build) - Verify with
bin\node.exe mxapp.js <command> param=value debug=1
V. Logs
- Path:
%TEMP%\MxNode(same convention on Linux) - Each command ends by printing
logs end; withdebug=1the log is more detailed - When the return is
{"code":-4,"message":"js program exception, see log for details"}, check the log file
VI. Bundled Resources
| File | Purpose |
|---|---|
empty_template.dwg | Blank template; Mx2DDraw.getEmptyTemplateDwgFilePath() points to it |
A3.dwg / BT.DWG | Title block frame / title block samples (the BT block contains attribute definitions); used by testParamDrawTk |
t1.dwg / tree.dwg | Test drawing / test block (the tree block is used by testParamDraw) |
mxcad_ini.json (in the conversion program directory) | Conversion program config (font paths, etc.); do not modify casually |
fonts\ | Font directory (SHX/TTF font dependencies of DWGs) |